MC55 AT Command Set

16.9 AT^SNFA

s

m

obile

MC55_ATC_V01.05

Page 403 of 469

2/10/04

Confidential / Released

16.9

AT^SNFA Set or query of microphone attenuation

Syntax

Command Description

The test command returns the supported values of the parameter

<atten>

.

The read command returns the current attenuation value on the microphone path for the current audio device
(selected by

AT^SNFS

).

Write command controls the large-scale attenuation on the microphone path for the current audio device
(selected by

AT^SNFS

) with the following restrictions:

• It is not allowed for audio device 1
• As long as the microphone is muted, the write command is temporarily disabled
• Setting of value 0 is not allowed (use

AT^SNFM

=0 for this).

• For values greater than 32767, 32767 will be used.

Test Command

AT^SNFA=?

Response(s)

^SNFA:

(list of supported

<atten>

s)

OK

Read Command

AT^SNFA?

Response(s)

^SNFA:

<atten>

OK

Write Command

AT^SNFA=

<atten>

Response(s)

OK

ERROR

CME ERROR: <err>

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

%

%

%

%

Reference(s)