MC55 AT Command Set

16.15 AT^SNFS

s

m

obile

MC55_ATC_V01.05

Page 415 of 469

2/10/04

Confidential / Released

Examples

EXAMPLE 1

Suppose a user wishes to use alternatively a handsfree device and a handset. The handset can be connected
to the first analog interface and adjusted to audio mode 4. The handsfree device can be attached to the sec-
ond analog interface and adjusted to audio mode 2. The factory defaults of

AT^SAIC

need not be changed.

Settings for the handset:

Settings for the handsfree device:

To store the configuration to the user defined audio profile:

To switch back and forth:

EXAMPLE 2

The following example illustrates a combination of a handset and a handsfree device connected to other inter-
faces than those assumed as factory default.
Settings for a handset connected to the second analog interface and adjusted to audio mode 4:

AT^SNFS=4

OK

AT^SAIC?

Factory default of AT^SAIC assigned to audio mode 4.

^SAIC: 2,1,1

OK

AT^SNFS=2

OK

AT^SAIC?

Factory default of AT^SAIC assigned to audio mode 2.

^SAIC: 2,2,2

OK

AT^SNFW

Stores the audio mode and the interface.

OK

AT^SNFS=4

Switches to the handset connected to analog interface 1.

OK

AT^SNFS=2

Switches to the handsfree device at analog interface 2.

OK

AT^SNFS=4

OK

AT^SAIC=2,2,2

OK