9 at^smso switch off mobile station, At^smso switch off mobile station, Shutdown – Siemens MC55 User Manual

Page 44: Obile

Advertising
background image

MC55 AT Command Set

2.9 AT^SMSO

s

m

obile

MC55_ATC_V01.05

Page 44 of 469

2/10/04

Confidential / Released

2.9

AT^SMSO Switch off mobile station

Syntax

Unsolicited Result Code

^SHUTDOWN

Indicates that the power-off procedure is finished and the module will be switched off within 1 second

Command Description

The exec command initiates the power-off procedure. Low level of the module's VDD pin and display of URC
"

^SHUTDOWN

" verifies that the procedure has completed and the module has entered the POWER DOWN mode.

Therefore, be sure not to disconnect the operating voltage until VDD is low or until URC "

^SHUTDOWN

" is dis-

played . Otherwise, you run the risk of losing data. For further details on how to turn off the module see the

[2]

.

Notes

• Do not send any command after this command.

• If AT^SMSO is entered on one of the Multiplexer channels the ME closes the Multiplexer channels, terminates

the Multiplexer and deactivates all other functions. Then, the URC "

^SHUTDOWN

" will be issued on the phys-

ical serial interface (ASC0). The URC will be transmitted at the bit rate last activated on ASC0 for use with
the Multiplex driver.

• If both interfaces ASC0 and ASC1 are connected the URC appears on both of them.

Test Command

AT^SMSO=?

Response(s)

OK

Exec Command

AT^SMSO

Response(s)

^SMSO:

MS OFF

OK

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

%

%

%

%

Reference(s)

SIEMENS

Advertising