MC55 AT Command Set

10.13 AT^SGCONF

s

m

obile

MC55_ATC_V01.05

Page 269 of 469

2/10/04

Confidential / Released

10.13

AT^SGCONF Configuration of GPRS related Parameters

Syntax

Parameter Description

LLC-PDU-length

0

no negotiation with network (500 will be used)

140...1520

(P)

lower values diminish performance

GPRS Multislot Class. The parameter can be changed only when the MT is detached, otherwise ''CME ERROR:
operation temporary not allowed'' will be returned. The value can be one of the classes indicated with the Test
command.

Test Command

AT^SGCONF=?

Response(s)

^SGCONF:

(list of supported

<llc_pdu_length>

s), (list of supported

<class>

es)

OK

Read Command

AT^SGCONF?

Response(s)

^SGCONF:

<llc_pdu_length>

,

<class>

OK

Write Command

AT^SGCONF=

[

<llc_pdu_length>

] [,

<class>

]

Response(s)

OK

ERROR

+CME ERROR

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

%

%

%

%

Reference(s)

SIEMENS

<llc_pdu_length>

(num)

<class>

(num)