9 at+fdcc query or set capabilities, Obile, Mc55 at command set – Siemens MC55 User Manual

Page 292

Advertising
background image

MC55 AT Command Set

11.9 AT+FDCC

s

m

obile

MC55_ATC_V01.05

Page 292 of 469

2/10/04

Confidential / Released

11.9

AT+FDCC Query or set capabilities

Syntax

Command Description

This command allows the connected application to sense and constrain the capabilities of the facsimile DCE
(=ME), from the choices defined in CCITT T.30 Table 2.

Notes

• For further information see

AT+FDIS

.

• Used for Fax Class 2 only

Test Command

AT+FDCC=?

Response(s)

(list of

<vr>

s), (list of

<br>

s), (list of

<wd>

s), (list of

<ln>

s), (list of

<df>

s), (list of

<ec>

s), (list of

<bf>

s),

(list of

<st>

s)

OK

Read Command

AT+FDCC?

Response(s)

<vr>

,

<br>

,

<wd>

,

<ln>

,

<df>

,

<ec>

,

<bf>

,

<st>

OK

Write Command

AT+FDCC=

<vr>

,

<br>

,

<wd>

,

<ln>

,

<df>

,

<ec>

,

<bf>

,

<st>

Response(s)

OK

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

!

%

!

!

Reference(s)

EIA PN-2388