Audmode, Obile – Siemens MC55 User Manual

Page 414

Advertising
background image

MC55 AT Command Set

16.15 AT^SNFS

s

m

obile

MC55_ATC_V01.05

Page 414 of 469

2/10/04

Confidential / Released

Parameter Description

[1]

Audio mode 1: Standard mode optimized for the reference handset, that can
be connected to the analog interface 1 (see your "Hardware Interface Descrip-
tion" for information on this handset.) To adjust the volume use the knob of the
reference handset. In audio mode 4, this handset can be used with user
defined parameters.
Note: The default parameters are determined for type approval and are not
adjustable with AT commands.

AT^SNFD

restores

<audMode>

1.

2

Audio mode 2: Customer specific mode for a basic handsfree device (Siemens
Car Kit Portable).
Analog interface 2 is assumed as default.

3

Audio mode 3: Customer specific mode for a mono-headset.
Analog interface 2 is assumed as default.

4

Audio mode 4: Customer specific mode for a user handset.
Analog interface 1 is assumed as default.

5

Audio mode 5: Customer specific mode.
Analog interface 1 is assumed as default.

6

Audio mode 6: Customer specific mode.
Analog interface 2 is assumed as default.

Notes

• The write command can be used during a voice call to switch back and forth between different modes. This

allows the user, for example, to switch handsfree operation on and off.

• Users should be aware that

<outStep>

is a global setting. This means, when another audio mode is selected

during a call, the value of

<outStep>

does not change. This is also true for mute operation which can be set

with

AT^SNFM

or

AT+CMUT

: If the microphone is muted and the user selects another audio mode during the

call, then the microphone remains muted until explicitly changed. Exception: In audio mode 1

<outStep>

=4

is fix.

<audMode>

(num)(^SNFW)