At^sctm, Obile, Mc55 at command set – Siemens MC55 User Manual

Page 434

Advertising
background image

MC55 AT Command Set

17.5 AT^SCTM

s

m

obile

MC55_ATC_V01.05

Page 434 of 469

2/10/04

Confidential / Released

17.5

AT^SCTM Set critical operating temperature presentation mode
or query temperature

Use this command to monitor the temperature range of the module and the battery. The write command enables
or disables the presentation of URCs to report critical temperature limits.
CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report mode: URCs
can be always displayed regardless of the selected mode

<n>

.

Syntax

Unsolicited Result Codes

URC 1

URCs will be automatically sent to the TA when the temperature reaches or exceeds the critical level, or when
it is back to normal.

Test Command

AT^SCTM=?

Response(s)

^SCTM:

(list of supported

<n>

s)

OK

Read Command

AT^SCTM?

Response(s)

^SCTM:

<n>

,

<m>

OK

ERROR

+CME ERROR: <err>

Write Command

AT^SCTM=

<n>

Response(s)

OK

ERROR

+CME ERROR: <err>

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

%

%

%

%

Reference(s)