MC55 AT Command Set

2. Configuration Commands

s

m

obile

MC55_ATC_V01.05

Page 30 of 469

2/10/04

Confidential / Released

2.

Configuration Commands

The AT Commands described in this chapter allow the external application to determine the MC55's behaviour
under various conditions.

2.1

AT&F Set all current parameters to manufacturer defaults

Syntax

Command Description

TA sets all current parameters to the manufacturer defined profile.

Parameter Description

[0]

set all TA parameters to manufacturer defaults

Notes

• List of parameters reset to manufacturer default can be found in Chapter

Factory Default Settings

Restorable with AT&F

.

• In addition to the default profile, you can store an individual one with

AT&W

. To alternate between the two pro-

files enter either

ATZ

(loads user profile) or

AT&F

(restores factory profile).

• Every ongoing or incoming call will be terminated.

Exec Command

AT&F

[

<value>

]

Response(s)

OK

PIN

ASC0

ASC1

MUX1

MUX2

MUX3

!

%

%

%

%

%

Reference(s)

V.25ter