2.8 AT+CFUN

s

m

obile

MC55_ATC_V01.05

Page 43 of 469

2/10/04

Confidential / Released

2.8.1

Wake up the ME from SLEEP mode

A wake-up event is any event that causes the ME to draw current. Depending on the selected mode, the wake-
up event either switches the SLEEP mode off and takes the ME back to full functionality

AT+CFUN

=1, or activates

the ME temporarily without terminating the selected SLEEP mode.

Definitions of the state transitions described in Table

2.3

:

• Quit: ME exits SLEEP mode.
• Temporary: ME becomes active temporarily for the duration of the event and the mode-specific follow-up time

after the last character was sent or received on the serial interface.

• No effect: Event is not relevant in the selected SLEEP mode. The ME does not wake up.

Table 2.3:

Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes

Event

Selected mode:

<fun>

=0

Selected mode:

<fun>

=5 or 6

Selected mode:

<fun>

=7 or 8 or 9

Ignition line

No effect

No effect

No effect

/RTS0 or /RTS1 activation Quit

No effect (RTS is only
used for flow control)

Mode 7 and 8: No effect
(RTS is only used for flow
control)
Mode 9: Temporary

Unsolicited Result Code
(URC)

Quit

Quit

Temporary

Incoming voice or data
call

Quit

Quit

Temporary

Any AT command (incl.
outgoing SMS, voice or
data call)

Not possible (UART dis-
abled)

Temporary

Temporary

Incoming SMS (

AT+CNMI

is set to 0,0 (this is the
default setting)

No effect

No effect

No effect

Incoming SMS (

AT+CNMI

is set to 1,1)

Quit

Quit

Temporary

GPRS data transfer

Not possible (UART dis-
abled)

Temporary

Temporary

RTC alarm line

Quit

Quit

Temporary

AT+CFUN

=1

Not possible (UART dis-
abled)

Quit

Quit