Cablelength short (controller context) – Avaya X330WAN User Manual

Page 138

Advertising
background image

Chapter 6

X330WAN CLI Commands

116

Avaya X330WAN User’s Guide

Note:

If you can not configure the hardware’s receive sensitivity, the receive

sensitivity is fixed at 36 dB and is unaffected if you enter

gain26

or

gain36

.

Example

X330WAN-2DS1-1(config-controller:1)# no cablelength

The following example changes the CLI receive sensitivity to match the actual
receive sensitivity of the hardware and adds 15 dB of attenuation to the transmit
signal:

X330WAN-2DS1-1(config-controller:1)# cablelength long gain36 -15db

cablelength short (Controller context)

Use the

cablelength short

command to configure transmit attenuation for a

cable length (line build-out) of 655 feet or shorter for a T1 trunk with a DSX-1
interface. This command configures the attenuation using the loop length. The

no

form of this command restores the default value.

Note:

This command can only be performed if the controller is set to T1.

Syntax

cablelength short

{133ft|266ft|399ft|533ft|655ft}

Parameters

-7.5db

Sets the transmit attenuation to 7.5 dB.

0db

Sets the transmit attenuation to 0 dB. This is the default value.

133

Cable length of 0 to 133 feet. This is the default value.

266

Cable length of 134 to 266 feet.

399

Cable length of 267 to 399 feet.

533

Cable length of 400 to 533 feet.

655

Cable length of 534 to 655 feet.