Controller CLI Commands (X330WAN-2DS1 Only)

Avaya X330WAN User’s Guide

119

Parameters

Note:

Only one E1/T1 controller at a time can recover the network clock and

distribute it to the internal clock generator.

Example

X330WAN-2DS1-1(config-controller:1)#

clock source internal

X330WAN-2DS1-1(config-controller:1)#

no clock source

controller

Use the

controller

command to enter the specified controller's mode.

Note:

You can not configure one controller as E1 and the other as T1.

Syntax

controller

{ e1 | t1 } <port>

Parameters

Example

X330WAN-2DS1-1(configure)# controller E1 2

line

The controller recovers the external clock from the line and provides
the recovered clock to the internal (system) clock generator. This is
the default value.

internal

The controller synchronizes itself to the internal (system) clock.

e1

An E1 port.

t1

A T1 port.

port

The number of the port that is being configured.