System options – CTL Lx-Lite VoiceSupport User Manual

Page 116

Advertising
background image

System Options

3-82

VoiceSupport LX System Guide

Chapter 3 Customizing Voice Mail

Call Announce Message Length - Sets the maximum length in seconds for
the name that the Automated Attendant caller will record in the Call
Announcing feature.

For First Protocol Digit - Sets the maximum time interval in seconds (0-99)
that the Voice Mail will wait for the first digit of the protocol string of a call
from the phone system, after the call enters a Voice Mail port. If the Voice
Mail does not receive the first digit within the specified wait time, the Voice
Mail will handle the call by using the Answering Schedule Table. The
telephone system that is installed will determine the duration of the wait
time.

For Subsequent Protocol Digit - Sets the maximum time interval in
seconds (0-99) that the Voice Mail will wait for each subsequent digit after
receiving the first digit of a call’s protocol string. If it does not receive the
digit within the specified wait time, the Voice Mail will handle the call by
using the Answering Schedule Table. The telephone system that is installed
will determine the duration of the wait time.

After Last Protocol Digit - Sets the maximum time interval in seconds
(1-240) that the Voice Mail will wait for the Hang Up string, after it receives
the last digit of a call’s protocol string. If the Voice Mail does not receive the
Hang Up string within the specified wait time, the Voice Mail will handle the
call by using the Answering Schedule Table. The telephone system that is
installed will determine the duration of the wait time.

Silent Limit for Recording - Sets the maximum time in seconds (1-25) that
someone can be silent while recording, before the Voice Mail will pause the
recording and say, Recording has been paused due to silence.

Message Backup/Go-Ahead Timer - Sets the maximum time interval in
seconds (1-60) so that the Voice Mail will back up a message when a user
presses B or will fast forward a message when a user presses G.

Page/Meet-Me Page Hold Timer - Sets the maximum time interval in
seconds (1-240), that will be allowed to the call receiver, after the Voice Mail
pages the call receiver by using Paging/Meet-Me Paging, an Automated
Attendant feature.

Flash Timer - This value sets the length of the Flash (1-999). The value “1”
represents 10 milliseconds.

Hang Up Timer - Sets the minimum time interval in seconds (1-999) that the
Voice Mail will wait after terminating a call, before making another call. The
value “1” represents 10 milliseconds. You can enter a Hang Up code (H) in
any string that allows special codes, such as a pause.

5) Click the Apply changes button.