Metrohm 788 IC Filtration Sample Processor User Manual

Page 11

Advertising
background image

1.2 Parts and controls

788 IC Filtration Sample Processor

3

1111

Splash protection (6.2751.040)

Must be installed always in operation!

19

19

19

19

PEEK coupling (6.2744.030) (Olive)

Connecting compression fitting and

pump tubing

2222

Needle

PEEK needle (6.1835.010) or

PEEK tubing (6.1835.020)

20

20

20

20 PEEK capillary (6.1831.060) (1 m)

For conveying the filtrate into the

sample loop

3333

Lift

With swing head attached

21

21

21

21 PTFE capillary (6.1803.050)

(0.5 mm / 0.2 m) Connecting ultra-

filtration cell and filtrate pump tubing

4444

Needle guide (4.766.4330)

Attached (part of needle holder

(6.2833.000))

22

22

22

22 PVDF compression fitting

(6.2744.000) Connecting PTFE capillar-

ies (6.1803.0X0) to ultra-filtration cell

5555 PEEK compression fitting

(4.766.4320) For PEEK needle or tubing

23

23

23

23 Ultra-filtration cell (6.2729.110)

(Plexiglass)

6666

PEEK compression fitting

(6.2744.010) For connection of PEEK or

PTFE capillaries 1/16 "

24

24

24

24 PTFE capillary (6.1803.060)

(0.97 mm / 0.2 m) Connecting sample

pump tubing and ultra-filtration cell

7777

Swing head

Attached

25

25

25

25 PTFE capillary (6.1803.080)

(0.97 mm / 1 m) Connecting ultra-

filtration cell and waste

8888

PTFE capillary (6.1803.070)

(0.97 mm / 0.40 m)

Connection

needle – pump tubing

26

26

26

26 Cell holder

For ultra-filtration cell

9999

Guide chain

For fixing tubings and cables

27

27

27

27 Tower

10

10

10

10 Pump tubing (6.1826.070)

(yellow/yellow) Conveying the sample

to the ultra-filtration cell

28

28

28

28 PE bottle (6.1608.080) (300 mL)

11

11

11

11 Pump tubing (6.1826.030)

(orange/yellow) Conveying the filtrate

to the sample loop

29

29

29

29

Connection cable for swing head

Attached, incl. branch plug for remote

connection

12

12

12

12

Screw thread for splash protection

30

30

30

30

Remote connection

For additional Metrohm instruments

13

13

13

13

Mounting pin

For attaching the tubing cartridges

31

31

31

31

Plug cover (6.2752.010)

14

14

14

14

Tubing cartridge (6.2755.000)

For pump tubing (6.1826.0X0)

32

32

32

32

Fuse holder

Changing the fuses, see section 2.2.2

15

15

15

15

Pump drive

Roller head with contact rollers

33

33

33

33 Mains connection plug

Mains connection, see section 2.2.3

16

16

16

16

Snap-action lever

For releasing the tubing cartridge

34

34

34

34 Mains switch

For switching the instrument on/off:

I = ON 0 = OFF

17

17

17

17

Holding clamp

For locking the tubing cartridge into

place

35

35

35

35

Sample rack (6.2041.430)

18

18

18

18 Contact pressure lever

For adjusting the contact pressure

36

36

36

36

PP sample tube (6.2743.050) (11 mL)

Can be sealed with 6.2743.070 PP caps