Controlling Power of a KVM-connected Server

In order to control power of a server while connected to the server, the
following conditions must be met:

The server must have at least one power cord plugged into an AlterPath
PM that is properly configured and connected to the AUX port.

The power outlet(s) that the server is connected to must be configured to
the port.

If a regular user is accessing this device, the user must have the following
permissions:

• Full control (read, write, power) permission on the port,

• Permission to control power on the PM outlet that the device is plugged

into.

T

To Power On, Power Off, or Reboot the
Connected Server

1. While connected to a server, use the power management keyboard

shortcut.

The default is Ctrl+k p.

A window similar to the following appears.

2. Select the configured outlet.

3. Do one of the following:

• To turn the power on, select On.

• To turn the power off, select Off.

• To reboot, select Cycle.

To lock or unlock outlets, you must go to the Power Management menu.
See “Power Management” on page 343 for more information.