23

Cascaded Devices

Administrators can connect up to 32 KVM units to the master KVM/net. Each
cascaded KVM device has two management ports that can be connected to the
primary KVM/net.

Note: You must connect the master KVM/net’ KVM port to User 2 on the slave.

Optionally, you can add a second connection to User 1 on the slave by using a
terminator. If a KVM Expander is used then User A or User B management
ports on the KVM Expander can be used.

Note: In a cascaded configuration, the internal IP modules of the cascaded units are

not available.

The following table indicates which ports on each cascaded device can be
used for cascading and which cables need to be used in order to connect them.

Table 1-8: Connectors and Ports for Cascading KVM Units

KVM Unit

Management Ports

Connectors

KVM Expander

User B primary

User A secondary

CAT5 cable with RJ45
connectors

AlterPath KVM

User 2 primary

User 1 secondary

CAT5 cable

KVM Terminator (User1)
and CAT5 cable with RJ45
connectors

AlterPath
KVM/net

User 2 primary

User 1 secondary

CAT5 cable

KVM Terminator (User1)
and CAT5 cable with RJ45
connectors

AlterPath
KVM/netPlus

User 2 primary

User 1 secondary

CAT5 cable

KVM Terminator (User1)
and CAT5 cable with RJ45
connectors