To determine the boundary of fault detection for selected zone. There is a fault recognized if one

of follow conditions is true:

Measure < (Full Loaded Reference x (100% - Tolerance%))

Measure > (Unloaded Reference x (100% + Tolerance%))

Get Reference

Get the reference values of selected zone for further fault detection. Be aware, hardware

configuration(IDA8C/S, amplifiers, wiring) should be done before get reference.

Reset Reference

Clear reference values of selected zone to go back initial status. if reference value is cleared,

monitoring will be stopped.

Measurement

After parameter settings are done in lower part grid, IDA8C/S start to measure value get from internal

circuit, and display it on the grid at upper part of window:

Unloaded Reference

Display the value of unloaded reference which is the gain of amplifier when there is no load to

the zone. This value use to determine if there is a fault of normal amplifier or not.

Full Loaded Reference

Display the value of full loaded reference which is the gain of amplifier when there is full load to

the zone. This value use to determine if there is a fault of normal amplifier or not.

Measure

Display the value of measured which is the gain of amplifier.