No preset error, Spi flash error, No preset table – ATEIS IDA8C User Manual

Page 73

Advertising
background image

Product Features

73

© 2012 ATEÏS

1. Update firmware using newest version of Ateis Studio.

2. Store configuration. It the problem still not solved, please contact service.

4.1.6.1.6 No Preset Error

Fault Meaning

There is no configuration inside device.

Fault Indication

LED Indicator

When this error is detected, following LEDs will light up:
o System Fault LED on front panel of IDA8C/S.
o G. Fault LED on front panel of IDA8C/S.

Log

Text messages display at touch screen on front panel of IDA8C:

"No Preset Table"

Text message display at window [Machine Fault Record] of Ateis Studio:

Buzzer sound output to monitoring speaker on front panel of IDA8C.

Fault Handling

Store a configuration to device. If the error still not solved please contact service.

4.1.6.1.7 SPI Flash Error

Fault Meaning

An internal error of micro controller SPI communication.

Fault Indication

LED Indicator

When this error is detected, following LEDs will light up:
o System Fault LED on front panel of IDA8C/S.
o G. Fault LED on front panel of IDA8C/S.

Log

Text messages display at touch screen on front panel of IDA8C:

"SPI Flash Error"