4.1.6.2.2 Line A/B Error

Fault Meaning

This error is mainly for loudspeaker connected to IDA8C/S's speaker zone output connectors, there

are three kind of faults:

Line A/B Open

If the value of Measure (ohm) is greater than 4000 ohm, this fault can be recognized by IDA8C/

S, In the field of [Measure(ohm)] shows "OPEN".

Line A/B Bad Impedance

If the value of Measure (ohm) is greater than Reference A&B (ohm) + Tolerance (%), or value of

Measure (ohm) is less than Reference A&B (ohm) - Tolerance (%), this fault can be recognized

by IDA8C/S. In the field of [Diff(%)] shows the percentage of difference, in above figure, the

difference percentage of zone 4 is 78.24 which is great than the tolerance 15%, a Line A/B bad

impedance is recognized.

Line A/B Short