Rear panel – ATEIS IDA8C User Manual

Page 208

Advertising
background image

Ateis Studio

208

© 2012 ATEÏS

checking the level of the input signal.

Temp.

If the device internal temperature exceeds 95 degrees C, the TEMP LED will light and the pre-amp

will stop working until the temperature falls below 95 degrees C. The pre-amp will come back to a

working state automatically. To avoid temperature failure, please insert an external fan to the rack

system.

DC

The DC LED indicates that the SPA amplifier is powered by a 24VDC power supply.

Power

The Power LED indicates the ON/OFF status of the SPA amplifier.

4.3.1.3 Rear Panel

Fuse Receptacles

Two fuse receptacles are located on the left of the amplifier’s rear panel.

Power Switch

The power switch is located at the left of the rear panel and is a two position switch. Pushing up the

power switch (I is pushed) will power on the device, pushing it down (0 is pushed) will power it off.

When the power switch is on the I position, the front panel power LED will be lit.

Channel 1/2 24VDC battery backup connector

The SPA amplifier can be operated with battery backup. Use the channel 1 and channel 2 “24VDC

Battery Backup” connector to do so. These connectors are located on the upper part of the channel

connectors on the rear panel.

This 24VDC power supply can be used where no AC power is available. When in use, the front panel

Power LED will be lit as well as the front panel DC LED.

AC Power Inlet

The 3 pin IEC connector is located on the left of the amplifier’s rear panel. It accepts a standard

Advertising