Remote offline – ATEIS IDA8C User Manual

Page 92

Advertising
background image

Ateis Studio

92

© 2012 ATEÏS

o G. Fault LED on front panel of IDA8C/S.

Log

Text messages display at touch screen on front panel of IDA8C:

"User Define Er."

"XXXXX", where XXXXX is the content defined in "Fault Definer" DSP component field

[Message].

Text message display at window [Machine Fault Record] of Ateis Studio:

Buzzer sound output to monitoring speaker on front panel of IDA8C.

Fault Handling

Define on the configuration of DSP component. Basically, you need check the component which is

the input of "Fault Definer".

4.1.6.2.9 Remote Offline

Fault Meaning

IDA8C/S can't communicate with peripheral devices.

Fault Indication

LED Indicator

When this error is detected, following LEDs will light up:
o G. Fault LED on front panel of IDA8C/S.

Log

Text messages display at touch screen on front panel of IDA8C:

"Remote Offline"

"PPM Port:2 ID:1", where Port N is the N

th

PDC port for peripheral connection, ID is the

unique number for each peripheral device on the PDC port.

Text message display at window [Machine Fault Record] of Ateis Studio:

Buzzer sound output to monitoring speaker on front panel of IDA8C.

Advertising