Vox@net error – ATEIS IDA8C User Manual

Page 90

Advertising
background image

Ateis Studio

90

© 2012 ATEÏS

o Fireman Microphone Button Open

Text messages display at touch screen on front panel of IDA8C:

"Fireman Error"

"Fireman Button Open"

Text message display at window [Machine Fault Record] of Ateis Studio:

o Fireman Microphone Button Short

Text messages display at touch screen on front panel of IDA8C:

"Fireman Error"

"Fireman Button Short"

Text message display at window [Machine Fault Record] of Ateis Studio:

Buzzer sound output to monitoring speaker on front panel of IDA8C.

Fault Handling

Check the wire connection of fireman microphone.

If wire connection is fine but still get fault, change fireman microphone to a good one.

If fireman microphone is changed but still get fault, change IDA8C or contact service.

4.1.6.2.7 VOX@NET Error

Fault Meaning

IDA8C/S can't communicate with VOX@NET server.

Fault Indication

LED Indicator

When this error is detected, following LEDs will light up:

Advertising