296

© 2012 ATEÏS

level is not stable around0 dB, user could adjust the gain of output function, amplifier or

sensing microphone to let AGC level stable around 0 dB.

When the system is calibrating, clicking on the calibration button will cancel the calibration at

that moment. (The system will use the calibration result which was successfully calibrated at

last time.)

After calibration successful, the paging microphone shouldn't be placed nearly to sensing

microphone.(because the user's voice will be also received into sensing microphone.)

AGC level is still calculating even in inactivate mode.The level is depend on background

noise. It will support a good initial gain for paging level.

Use the A.N.G

When the calibration green led lit, the system is ready. In our example, the A.N.G has detected an

ambient noise average of -12dB. We choose a medium "response speed" and a short "sampling

time" to be enough reactive quickly.

Now the A.N.G will automatically adjust the level on the (P.M) signal depending on the ambient

noise detected on the sensing microphone. The A.N.G will working when the paging activity led will

light, meaning that an audio signal is detected on the (P.M) input.
Dead Zone:
If the sensing microphone doesn't detect more noise than during the calibration, the A.N.G works in

the "Dead Zone" which means that there is no need to adjust the gain.