Ateis Studio

82

© 2012 ATEÏS

The voltage of pin +, - is monitored by IDA8C/S, if the voltage is zero, it means there is a short

of circuit outside IDA8C/S, if this fault is detected, the internal relay of zone will be open to stop

audio signal output to speaker. User need to do a Reset Monitoring described in preview part of

this topic to switch the status back, i.e. make audio output to speaker and enable monitoring of

short again. A string "S.C." is showed in field [Measure(ohm)]

Fault Indication

LED Indicator

When this error is detected, following LEDs will light up:
o G. Fault LED on front panel of IDA8C/S.
o Zone Fault LEDs on front panel of IDA8C/S.

Log

o Line A/B Open

Text messages display at touch screen on front panel of IDA8C:

"Line A Error", where Line A can be Line B.

"Z1 Line A OPEN", where Z1 can be any zone, Line A can be Line B.

Text message display at window [Machine Fault Record] of Ateis Studio:

o Line A/B Bad Impedance

Text messages display at touch screen on front panel of IDA8C:

"Line A Error", where Line A can be Line B.

"Z1 Line A Bad Impedance", where Z1 can be any zone, Line A can be Line B.

Text message display at window [Machine Fault Record] of Ateis Studio:

o Line A/B Short

Text messages display at touch screen on front panel of IDA8C:

"Line A Error", where Line A can be Line B.

"Z1 Line A SHORT-OPEN", where Z1 can be any zone, Line A can be Line B.

Text message display at window [Machine Fault Record] of Ateis Studio: