ATEIS IDA8C User Manual

Page 387

Advertising
background image

Components of Audio Processor

387

© 2012 ATEÏS

The Occurrence parameter determines the cycle type of triggering, there are five types available:

Hourly/Daily/Weekly/Monthly/Yearly. It allow user to define the interval between cycles by

specify the parameter of Every N cycle units, where cycle unit could be Hour/Day/Week/Month/

Year.

In the box of List of Triggering Time, you can add or remove the triggering time in the cycle.

By Excel File

It allow user specify triggering times using an excel file, the rules are listed below:

Field A1 is the Year.Month to scheduling.

B1 ~ X1 is the field for time format, there are two choose:

o 24HR
o AM/PM

A2 ~ A 32 represent the day of a month.

For each row, B to X fields are the time to be trigged.

Exception Duration

Event the mechanism for triggering time setup is very flexible, but there still always need the

exceptions. On the lower part of scheduler settings window, A block Exception Duration allow user

to edit a list for the exceptions of the triggering, each exception consist of a start time and stop

time. During the exception time, all triggering will be masked.

Advertising