Procedure of monitoring setup – ATEIS IDA8C User Manual

Page 95

Advertising
background image

Product Features

95

© 2012 ATEÏS

o PPM AS / PSS AS Capsule Microphone Short

Text messages display at touch screen on front panel of IDA8C:

"Remote Fault"

"PSS Port:1 ID:1, Microphone Fault", where Port N is the N

th

PDC port for peripheral

connection, ID is the unique number for each peripheral device on the PDC port.

Text message display at window [Machine Fault Record] of Ateis Studio:

o PPM AS / PSS Speaker Error

Text messages display at touch screen on front panel of IDA8C:

"Remote Fault"

"PSS Port:1 ID:1, Speaker Fault", where Port N is the N

th

PDC port for peripheral

connection, ID is the unique number for each peripheral device on the PDC port.

Text message display at window [Machine Fault Record] of Ateis Studio:

Buzzer sound output to monitoring speaker on front panel of IDA8C.

Fault Handling

Replace the error peripheral device by a good one, and contact service to repair bad one.

4.1.6.3 Procedure of Monitoring Setup

The monitoring setup must be done when hardware setup is appropriate, it means IDA8C/S, amplifiers,

speakers, wiring should be prepared and connected before monitoring setup, because IDA8C/S will get

values of hardware initial state for further reference, when system is running and reference values are

appropriate achieved, IDA8C/S continuity measure internal status and compare with referenced values to

determine if there are something wrong of zone/amplifiers or not.

1. Setup hardware equipment, including IDA8C/S, normal amplifier, backup amplifier, speakers, wiring

between devices,

2. Make a configuration using Ateis Studio.