ATEIS IDA8C User Manual

Page 65

Advertising
background image

Product Features

65

© 2012 ATEÏS

backup amplifier can serve for zone 1 to zone 4 actually. The below figure shows the concept of that.

Share the Backup Amplifier

In the figure, Z1~Z4 represent the normal amplifier for Z1~Z4, B1 is backup amplifier. S1~S4 are

switches to select path of audio signal coming from DSP processing. S5~S8 are switches to select

path going to Line A/B output. B1 can service for zone1 to zone 4 by controlling switches S1~S8. In

example, amplifier Z2 is fail, IDA8 control S6 and S2 to change audio path from normal amplifier Z2

to backup amplifier B1. The behavior of other channels are the same as channel2. A backup

amplifier can't serve more than one zone at the same time. In such limitation, for example, if

amplifier Z3 is fail, then there is no available amplifier for backup.

Advance Backup Amplifier Setup

There are more cost down solution of IDA8 backup amplifier setup. It is possible to let one backup

amplifier serve more than four zones. See the below figure, an Ateis Net system is consist of one

IDA8C and two IDA8Ss, there are 24 zones in the system divide into three backup amplifier groups.

For each group, there is an backup amplifier to redundant if any of normal amplifier in the group is

failure. To group zones, you need to wiring AMPI and AMPO between backup amplifier connectors.

red wires show the wire connections to group zones.