Table of system faults – ATEIS IDA8C User Manual

Page 69

Advertising
background image

Product Features

69

© 2012 ATEÏS

When a fault is generated, the following things will be done by IDA8/S:

System Fault LED is light on if the fault is a system fault, Fault. G.Fault LED is light on if the fault

is a global fault.

Fault State Output contact open.

Log the fault

A warning message for the fault will show in Touch Screen.

When Ateis Studio is connect to IDA8C/S, in [Device Status] field of [Device Management] panel

will show fault. Below is an example:

There is a warning tone will be generate by monitoring speaker.

A text message is showed in PSS touch screen, below figure is an example.

4.1.6.1 Table of System Faults

Name

Description

Flash Error

Nand flash inside IDA8C/S is error.

I2C Error

This is an internal error of I2C communication between micro

controllers

Net Card Error

This is error about bad communication between main cpu in IDA8C/

S and net card.

DSP Error

It's an internal error of communication between micro controllers

inside devices.

Preset Table Error

The structure of configuration is not compatible with current

firmware.

No Preset Table

There is no configuration inside device.

SPI Flash Error

An internal error of micro controller SPI communication.

Para. Table Error

Data error of table which store some important information of

configuration.