Configuring link monitoring, Configuring errored symbol event detection, Configuring errored frame event detection – H3C Technologies H3C S3100 Series Switches User Manual

Page 1032

Advertising
background image

1-7

To do…

Use the command…

Remarks

Enter system view

System-view

Configure the Ethernet OAM
handshake packet transmission
interval

oam timer hello interval

Optional

1000 millisecond by default

Configure the Ethernet OAM
connection timeout timer

oam timer keepalive interval

Optional

5000 milliseconds by default

After the timeout timer of an Ethernet OAM connection expires, the local OAM entity ages out its

connection with the peer OAM entity, causing the OAM connection to be disconnected. Therefore, you

are recommended to set the connection timeout timer at least fives times the handshake packet

transmission interval, thus ensuring the stability of Ethernet OAM connection.

Configuring Link Monitoring

After Ethernet OAM connections are established, the link monitoring periods and thresholds configured

in this section take effect on all Ethernet ports automatically.

Configuring Errored Symbol Event Detection

An errored symbol event occurs when the number of detected symbol errors over a specific detection

interval exceeds the predefined threshold.

Follow these steps to configure errored symbol event detection:

To do…

Use the command…

Remarks

Enter system view

system-view

Configure the errored
symbol event detection
interval

oam errored-symbol period period-value

Optional

1 second by default

Configure the errored
symbol event triggering
threshold

oam errored-symbol threshold
threshold-value

Optional

1 by default

Configuring Errored Frame Event Detection

An errored frame event occurs when the number of detected error frames over a specific interval

exceeds the predefined threshold.