H3C Technologies H3C S3100 Series Switches User Manual

Page 884

Advertising
background image

1-16

To do…

Use the command…

Remarks

Configure the type of
service

tos value

Optional

By default, the service type is zero.

Start the test

test-enable

Required

Display test results

display hwping results
[ admin-name operation-tag ]

Required

The display command can be executed in
any view.

8) Configuring UDP test on HWPing client

Follow these steps to configure UDP test on HWPing client:

To do…

Use the command…

Remarks

Enter system view

system-view

Enable the HWPing
client function

hwping-agent enable

Required

By default, the HWPing client function is disabled.

Create an HWPing test
group and enter its view

hwping
administrator-name
operation- tag

Required

By default, no test group is configured.

Configure the test type

test-type { udpprivate |
udppublic }

Required

By default, the test type is ICMP.

Configure the
destination address

destination-ip ip-address

Required

This IP address and the one configured on the
HWPing server for listening service must be the same.

By default, no destination address is configured.

Configure the
destination port

destination-port

port-number

z

Required in a Udpprivate test

z

A Udppublic test is a UDP connection test on port
7. Use the hwping-server udpecho ip-address 7
command on the server to configure the listening
service port; otherwise the test will fail. No port
number needs to be configured on the client; any
destination port number configured on the client
will not take effect.

z

By default, no destination port number is
configured.

Configure the source IP
address

source-ip ip-address

Optional

By default, no source IP address is configured.

Configure the source
port

source-port port-number

Optional

By default, no source port is specified.

Configure the number of
probes per test

count times

Optional

By default, one probe is made per test.

Configure the data
packet size

datasize size

Optional

By default, the data packet size is 100 bytes.

Configure a stuffing
character string

datafill string

Optional

By default, the numbers between 0 and 255 are
stuffed into datagrams in a cyclically way.

Configure a test
description

description string

Optional

By default, no description information is configured.

Configure the maximum
number of history
records that can be
saved

history-records number

Optional

By default, the maximum number is 50.

Advertising