Snmp test, Network requirements, Network diagram – H3C Technologies H3C S3100 Series Switches User Manual

Page 896: Configuration procedure

Advertising
background image

1-28

Negative SD Number:30 Negative DS Number:24

Negative SD Sum:64 Negative DS Sum: 41

Negative SD average:2 Negative DS average:1

Negative SD Square Sum:200 Negative DS Square Sum:161

SD lost packets number:0 DS lost packet number:0

Unknown result lost packet number:0

[Sysname-hwping-administrator-Jitter] display hwping history administrator Jitter

HWPing entry(admin administrator, tag Jitter) history record:

Index Response Status LastRC Time

1 274 1 0 2000-04-02 08:14:58.2

2 278 1 0 2000-04-02 08:14:57.9

3 280 1 0 2000-04-02 08:14:57.6

4 279 1 0 2000-04-02 08:14:57.3

5 280 1 0 2000-04-02 08:14:57.1

6 270 1 0 2000-04-02 08:14:56.8

7 275 1 0 2000-04-02 08:14:56.5

8 263 1 0 2000-04-02 08:14:56.2

9 270 1 0 2000-04-02 08:14:56.0

10 275 1 0 2000-04-02 08:14:55.7

For detailed output description, see the corresponding command manual.

SNMP Test

Network requirements

Both the HWPing client and the SNMP Agent are H3C S3100 series Ethernet switches. Perform

HWPing SNMP tests between the two switches to test the time required from Switch A sends an SNMP

query message to Switch B (SNMP Agent) to it receives a response from Switch B.

Network diagram

Figure 1-7 Network diagram for the SNMP test

Configuration procedure

z

Configure SNMP Agent (Switch B):

# Start SNMP agent and set SNMP version to V2C, read-only community name to public, and

read-write community name to private.

<Sysname> system-view

[Sysname] snmp-agent

[Sysname] snmp-agent sys-info version v2c

[Sysname] snmp-agent community read public

[Sysname] snmp-agent community write private