1-1

1

Port Basic Configuration

Ethernet Port Configuration

Combo Port Configuration

Introduction to Combo port

A Combo port can operate as either an optical port or an electrical port. Inside the device there is only

one forwarding interface. For a Combo port, the electrical port and the corresponding optical port are

TX-SFP multiplexed. You can specify a Combo port to operate as an electrical port or an optical port.

That is, a Combo port cannot operate as both an electrical port and an optical port simultaneously.

When one is enabled, the other is automatically disabled.

Configuring Combo port state

Follow these steps to configure the state of a Combo port:

To do…

Use the command…

Remarks

Enter system view

system-view

Enter Ethernet port view

interface interface-type
interface-number

Enable a specified Combo port

undo shutdown

Optional

By default, of the two ports in a
Combo port, the one with a
smaller port ID is enabled.

In case of a Combo port, only one interface (either the optical port or the electrical port) is active at a

time. That is, once the optical port is active, the electrical port will be inactive automatically, and vice

versa.

Initially Configuring a Port

Table 1-1 Initially configure a port

Operation

Command

Remarks

Enter system view

system-view

Enter Ethernet port view

interface interface-type
interface-number