Displaying rmon, Rmon configuration examples, Network requirements – H3C Technologies H3C S3100 Series Switches User Manual

Page 688: Network diagram, Configuration procedures

Advertising
background image

2-4

Displaying RMON

After the above configuration, you can execute the display command in any view to display the RMON

running status, and to verify the configuration.

Table 2-2 Display RMON

Operation

Command

Description

Display RMON statistics

display rmon statistics [ interface-type
interface-number |
unit unit-number ]

Display RMON history
information

display rmon history [ interface-type
interface-number |
unit unit-number ]

Display RMON alarm
information

display rmon alarm [ entry-number ]

Display extended RMON alarm
information

display rmon prialarm
[ prialarm-entry-number ]

Display RMON events

display rmon event [ event-entry ]

Display RMON event logs

display rmon eventlog [ event-entry ]

Available in any
view.

RMON Configuration Examples

Network requirements

z

The switch to be tested is connected to a remote NMS through the Internet. Ensure that the SNMP

agents are correctly configured before performing RMON configuration.

z

Create an entry in the extended alarm table to monitor the information of statistics on the Ethernet

port, if the change rate of which exceeds the set threshold, the alarm events will be triggered.

Network diagram

Figure 2-1 Network diagram for RMON configuration

Configuration procedures

# Add the statistics entry numbered 1 to take statistics on Ethernet 1/0/1.

<Sysname> system-view

[Sysname] interface Ethernet 1/0/1

[Sysname-Ethernet1/0/1] rmon statistics 1

[Sysname-Ethernet1/0/1] quit

# Add the event entries numbered 1 and 2 to the event table, which will be triggered by the following

extended alarm.

[Sysname] rmon event 1 log

[Sysname] rmon event 2 trap 10.21.30.55