2 monitor link configuration, Introduction to monitor link, Monitor link configuration – H3C Technologies H3C S3100 Series Switches User Manual

Page 955

Advertising
background image

2-1

2

Monitor Link Configuration

Currently, only S3100-EI series Ethernet switches support the monitor link feature.

Introduction to Monitor Link

Monitor Link is a collaboration scheme introduced to complement for Smart Link. It is used to monitor

uplink and to perfect the backup function of Smart Link.

A monitor Link consists of an uplink port and one or multiple downlink ports. When the link for the uplink

port of a Monitor Link group fails, all the downlink ports in the Monitor Link group are forced down. When

the link for the uplink port recovers, all the downlink ports in the group are re-enabled.

Figure 2-1 Network diagram for a Monitor Link group implementation

Switch A

Eth1/0/1

Eth1/0/2

Eth1/0/3

Uplink

Downlink

As shown in

Figure 2-1

, the Monitor Link group configured on the device Switch A consists of an uplink

port (Ethernet1/0/1) and two downlink ports (Ethernet1/0/2 and Ethernet1/0/3). A member port can be

an Ethernet port, static LACP aggregation group, manual link aggregation group, or Smart Link group. A

Smart Link group can serve as the uplink port only.