Displaying poe configuration, Poe configuration example, Networking requirements – H3C Technologies H3C S3100 Series Switches User Manual

Page 669

Advertising
background image

1-6

z

In the case that the PSE processing software is damaged (that is, no PoE command can be
executed successfully), use the full update mode to upgrade and thus restore the software.

z

The refresh update mode is to upgrade the original processing software in the PSE through
refreshing the software, while the full update mode is to delete the original processing software in
PSE completely and then reload the software.

z

Generally, the refresh update mode is used to upgrade the PSE processing software.

z

When the online upgrading procedure is interrupted for some unexpected reason (for example, the
device restarts due to some errors), if the upgrade in full mode fails after restart, you must upgrade
in full mode after power-off and restart of the device, and then restart the device manually. In this
way, the former PoE configuration is restored.

Displaying PoE Configuration

After the above configuration, execute the display command in any view to see the operation of the
PoE feature and verify the effect of the configuration.

Table 1-10

Display PoE configuration

Operation

Command

Description

Display the PoE status of a specific port or
all ports of the switch

display poe interface

[ interface-type

interface-number

]

Display the PoE power information of a
specific port or all ports of the switch

display poe interface power
[ interface-type interface-number ]

Display the PSE parameters

display poe powersupply

Display the status (enabled/disabled) of the
PoE over-temperature protection feature on
the switch

display poe temperature-protection

Available in any
view

PoE Configuration Example

PoE Configuration Example

Networking requirements

Switch A is an S3100 series Ethernet switch supporting PoE, Switch B can be PoE powered.

z

The Ethernet 1/0/1 and Ethernet 1/0/2 ports of Switch A are connected to Switch B and an AP
respectively; the Ethernet 1/0/8 port is intended to be connected with an important AP.

z

The PSE processing software of Switch A is first upgraded online. The remotely accessed PDs are
powered by Switch A.

z

The power consumption of the accessed AP is 2,500 mW, and the maximum power consumption
of Switch B is 12,000 mW.

z

It is required to guarantee the power feeding to the PDs connected to the Ethernet 1/0/8 port even
when Switch A is under full load.