Loading the Boot ROM

Figure 1-6 Local loading using TFTP

Step 1: As shown in

Figure 1-6

, connect the switch through an Ethernet port to the TFTP server, and

connect the switch through the Console port to the configuration PC.

You can use one PC as both the configuration device and the TFTP server.

Step 2: Run the TFTP server program on the TFTP server, and specify the path of the program to be

downloaded.

TFTP server program is not provided with the H3C Series Ethernet Switches.

Step 3: Run the HyperTerminal program on the configuration PC. Start the switch. Then enter the BOOT

Menu.

At the prompt "Enter your choice(0-9):" in the BOOT Menu, press <6> or <Ctrl+U>, and then press

<Enter> to enter the Boot ROM update menu shown below:

Bootrom update menu:

1. Set TFTP protocol parameter

2. Set FTP protocol parameter

3. Set XMODEM protocol parameter

0. Return to boot menu

Enter your choice(0-3):

Step 4: Enter 1 in the above menu to download the Boot ROM using TFTP. Then set the following

TFTP-related parameters as required:

Load File name :switch.btm

Switch IP address :1.1.1.2

Server IP address :1.1.1.1

Step 5: Press <Enter>. The system displays the following information:

Are you sure to update your bootrom?Yes or No(Y/N)