Operation

Command

Description

Configure trunk port to permit
packets from the
remote-probe VLAN

port trunk permit vlan
remote-probe-vlan-id

Required

Return to system view

quit

Create a remote destination
mirroring group

mirroring-group group-id
remote-destination

Required

Configure the destination port
for the remote destination
mirroring group

mirroring-group group-id
monitor-port monitor-port

Required

Configure the remote-probe
VLAN for the remote
destination mirroring group

mirroring-group group-id
remote-probe vlan
remote-probe-vlan-id

Required

When configuring a destination switch, note that:

z

The destination port of remote port mirroring cannot be a member port of an aggregation group, or

a port enabled with LACP or STP.

z

Only an existing static VLAN can be configured as the remote-probe VLAN. To remove a

remote-probe VLAN, you need to restore it to a normal VLAN first. A remote port mirroring group

gets invalid if the corresponding remote port mirroring VLAN is removed.

Displaying Port Mirroring

After the above configurations, you can execute the display commands in any view to view the

mirroring running information, so as to verify your configurations.

Table 1-7 Display configuration of mirroring

Operation

Command

Description

Display port mirroring
configuration

display mirroring-group { group-id |
all | local | remote-destination |
remote-source }

Available in any view

Mirroring Configuration Example

Local Port Mirroring Configuration Example

Network requirements

The departments of a company connect to each other through S3100 Ethernet switches:

z

Research and Development (R&D) department is connected to Switch C through Ethernet 1/0/1.

z

Marketing department is connected to Switch C through Ethernet 1/0/2.

z

Data detection device is connected to Switch C through Ethernet 1/0/3

The administrator wants to monitor the packets received on and sent from the R&D department and the

marketing department through the data detection device.

Use the local port mirroring function to meet the requirement. Perform the following configurations on

Switch C.

z

Configure Ethernet 1/0/1 and Ethernet 1/0/2 as mirroring source ports.