Isdn bri interface module, Fic-4bse, Introduction – H3C Technologies H3C MSR 50 User Manual

Page 248: Interface attributes, Jumper settings

Advertising
background image

4-53

ISDN BRI Interface Module

z

FIC-4BSE

FIC-4BSE

Introduction

FIC-4BSE, the four-port ISDN BRI interface module, transmits, receives, and processes four channels
of ISDN BRI S/T data traffic on ISDN BRI S/T interfaces.

The FIC-4BSE differs from the FIC-4BS only in the way they set matched resistance for an ISDN BRI
S/T interface: the FIC-4BS uses jumpers while the FIC-4BSE uses DIP switches.

The FIC-4BSE can work in dial mode or leased line mode.

Interface attributes

The following table describes the interface attributes of the FIC-4BSE.

Table 4-45 Interface attributes of the FIC-4BSE

Attribute

Description

Connector RJ-45

Number of connectors

4

Cable

ISDN S/T cable

Protocol & standard

ITU-T I.430, Q.921, Q.931

Operating mode

z

ISDN dial-up

z

ISDN leased line

Supported service

z

ISDN

z

ISDN supplementary services

z

Multi-user number

z

Sub-addressing

z

Backup

Jumper settings

The FIC-4BSE uses jumpers to set matched resistance for ISDN BRI S/T interfaces. The use of
100-ohm resistance on an ISDN BRI S/T interface depends on jumper settings. The following figure
shows the jumper settings, where all the ISDN BRI S/T interfaces are using 100-ohm resistance.

Figure 4-65 Jumper settings of the FIC-4BSE (example)

S1

S2

S3

S4

S5

S6

S8

S7

2

3

0

1

The following table describes how to set jumpers.

Advertising
This manual is related to the following products: