Sic-1gec, Introduction, Interface attributes – H3C Technologies H3C MSR 50 User Manual

Page 28

Advertising
background image

2-8

When connecting the optical fiber, observe the following:

z

Do not over-bend the optical fiber. Its curvature radius must be no less than 10 cm (3.9 in).

z

Make sure that the Tx and Rx ends are correctly connected.

z

Make sure that the fiber ends are clean.

Invisible laser radiation may be emitted from the fiber-optic ports which are connected to lasers. To
protect your eyes against radiation harm, never stare into an open fiber-optic port.

Step1 Insert the SFP optical module into its corresponding slot.

Step2 Locate the Rx and Tx ports of the SIC-1FEF interface. Connect them to another device with two optical

fibers: Rx to Tx and Tx to Rx.

Step3 Power on the router and check the behavior of the LINK LED on the SIC-1FEF panel. ON means an

Rx link is present and OFF means the opposite. In the latter case, check the line status.

SIC-1GEC

Introduction

1-port 10/100/1000 Mbps electrical and fiber Ethernet interface SIC module (SIC-1GEC) has the
following functions:

z

Receipt, transmission and processing of GE data stream;

z

CE electrical and fiber interface access;

z

1000/100/10 Mbps on electrical interface;

z

1000 Mbps on fiber interface

For H3C MSR 20-40 and MSR 30/50 series routers, a SIC-1GEC interface module can only be installed
in SLOT2 or SLOT4.

Interface attributes

The attributes of SIC-1GEC interface are shown in the following table.

Table 2-7 Interface Attributes of the SIC-1GEC

Attribute

Description

Connector RJ-45

Interface type

MDI

Advertising
This manual is related to the following products: