Fic-1vt1, Introduction – H3C Technologies H3C MSR 50 User Manual

Page 286

Advertising
background image

4-91

Figure 4-115 Extending an E1 75-ohm unbalanced coaxial cable

Router

Network
devices
such as DDN

DB-15

Coaxial connector

BNC

BNC

75-ohm non-balanced coaxial cable

75-ohm E1 trunk cable

If the remote device has 120-ohm interface, it is needed to use a 75-ohm-to-120-ohm adapter or use a
120-ohm cable.

3) When the E1 cable is a 120-ohm balanced twisted pair cable:

z

Connect the RJ-45 connector of the cable to the RJ-45 port of the remote equipment, if there is no
need to extend the E1 cable, or

z

Connect the RJ-45 connector of the cable to the network connector and the other end of the
network connector to the network equipment through a 120-ohm E1 trunk cable, if cable extension
is needed.

Figure 4-116 Extend an E1 120-ohm balanced twisted pair cable

Router

Network
devices such
as DDN

DB-15

Network interface connector

RJ-45

RJ-45

120-ohm balanced twisted pair

120-ohm E1 trunk cable

Step4 Check the status of LINK LED on the FIC-1VE1 panel: ON means the link is connected and OFF

means the link is not connected. In the latter case, check the line.

FIC-1VT1

Introduction

1-port T1 voice interface module (FIC-1VT1) can handle dense voice signals in VoIP system. It
provides a CT1/PRI port, allowing the access of 24 channels of voice signals.

z

VCPM is provided to users together with FIC-1VT1. Users can select VPM module as needed.

z

VPM module is installed on the main board of FIC-1VT1.

Advertising
This manual is related to the following products: