System errors – Yokogawa Touch Screen GP20 User Manual

Page 370

Advertising
background image

5-16

IM 04L51B01-01EN

System Errors

Servicing is required when a system error occurs. Contact your nearest YOKOGAWA dealer for repairs.

Code Message

Description, Corrective Action, Ref. Section

901

ROM failure.

Servicing is required. Contact your nearest YOKOGAWA dealer

for repairs.

902

RAM failure.

911

A/D calibration value error.

912

A/D calibration error.

Check that the reference value is correct.

Check that the wiring is correct.

If the same message continues to appear even after you perform

the procedure above, servicing is required. Contact your nearest

YOKOGAWA dealer for repairs.

913

Incorrect number for the A/D calibration.

Select a number of a module that has been detected.

914

Failed to write A/D calibration value.

Failed to write A/D calibration values to the module. Check that

the module is installed correctly. Do not remove the module during

calibration.

If the same message continues to appear even after you perform

the procedure above, servicing is required. Contact your nearest

YOKOGAWA dealer for repairs.

915

Failed to receive A/D calibration value.

Failed to receive A/D calibration values from the module. Check

that the module is installed correctly. Do not remove the module

during calibration.

If the same message continues to appear even after you perform

the procedure above, servicing is required. Contact your nearest

YOKOGAWA dealer for repairs.

921

Memory acquisition failure.

Perform the following tasks.

1. Stop recording.

2. Save the measured data that is stored in internal memory to an

external storage medium.

3. Initialize the internal memory data.

If the same message continues to appear even after you perform

the procedure above, servicing is required. Contact your nearest

YOKOGAWA dealer for repairs.

922

The ethernet module is down.

Servicing is required. Contact your nearest YOKOGAWA dealer

for repairs.

923

A hardware test failed.

924

The backup battery is low.

925

Touch screen failure

Stop recording and other operations so that the power can be

turned off. Then, turn off the power and then back on.

If the same message continues to appear even after you perform

the procedure above, servicing is required. Contact your nearest

YOKOGAWA dealer for repairs.

951

Data are not written at the flash memory area for

production.

Servicing is required. Contact your nearest YOKOGAWA dealer

for repairs.

952

A SUM value of the flash memory area for production is

incorrect.

953

The reading of the flash memory area for production

failed.

954

The writing of the flash memory area for production

failed.

999

System error.

5.2 Troubleshooting

Advertising