4 setting alarms, Setting alarms -61, App 1.5.4 setting alarms – Yokogawa Touch Screen GP20 User Manual

Page 75: Level 1, level 2, level 3, level 4

Advertising
background image

1-61

IM 04L51B01-01EN

Configuring the GX/GP

1

2

3

4

5

App

1.5.4

Setting Alarms

Path

GX/GP:

MENU key > Browse tab > Setting > Setting menu Math channel settings >

Alarm

Web browser:

Config. tab > Math channel settings > Math channel settings > Channel

range (display example: A001-A020)

Hardware configurator:

Config. tab > Math channel settings > Math channel settings >

Channel range (display example: A001-A020)

Description

Setup Item

Selectable Range or Options

Default Value

First-CH

GX20/GP20: A001 to A100

GX10/GP10: A001 to A050

A001

Last-CH

Same as the first channel

A001

First-CH, Last-CH

Set the target channels.

Level 1, Level 2, Level 3, Level 4

Setup Item

Selectable Range or Options

Default Value

On/Off

Off, On

Off

Type

1

H: High limit, L: Low limit, T: Delay high limit,

t: Delay low limit

H: High limit

Value

1

-9999999 to 99999999

0

Hysteresis

1, 3

Numeric value (0 to 100000)

0

Logging

1

Off, On

On

Output type

1

Off, Relay, Internal switch

Off

Output No.

2

DO channel or internal switch

1 Appears when On/Off is set to

On.

2 Appears when Output type is not set to

Off.

3 Appears when the type is set to

H:High limit or L:Low limit.

On/Off

To use an alarm level (1 to 4), set this to

On.

Type

Set the alarm type.

For details, see page 1-17 in section 1.2.2, “Setting Alarms”.

Value

Set the alarm value for the specified alarm type.

Options

Value

Examples of Alarm Value Range

H, L

–5% to 105% of span

However, within –9999999 to

99999999 excluding the decimal point.

When the scale is 0.0 to 100.0

–5.0 to 105.0

T, t

Same as H and L

Same as H and L

1.5 Configuring Math Channels