External Dimensions

M3 screw terminal

107.1(4.22)

26

(1.02)

92(3.62)

100(3.94)

3(0.12)

8(0.31)

(0.07)

1.9

45.1(1.78)

43.8(1.72)

Unit: mm

(approx. inch)

Clamp terminal

107.1(4.22)

26

(1.02)

92(3.62)

100(3.94)

3(0.12)

8(0.31)

(0.07)

1.9

45.1(1.78)

43.8(1.72)

Unit: mm

(approx. inch)

Normal Operating Conditions

Same as the GP main unit

Transport and Storage Conditions

Same as the GP main unit

Effects of Operating Conditions

• Influence of ambient temperature: variation against a

change of 10 °C at an accumulation time of 16.67 ms

or more ± (0.05% of rdg + 0.05%) or below

KpvsAu7Fe, PR20-40: ±(0.05% of rdg + 0.1%) or

below, Cu10Ω: ±(0.2% of rdg + 0.1 °C) or below

No reference contact accuracy is guaranteed.

• Influence of power supply voltage variation:

Accuracy is satisfied in the range of rated power

supply voltage.

• Influence of external magnetic field: Variations

against an AC external magnetic field (50/60 Hz,

400 A/m) are ±(0.1% of rdg+ 0 .1%) or below.