Tlog, Decimal place, Span lower, span upper – Yokogawa Touch Screen GP20 User Manual

Page 64: Unit, Timer type, Timer no, Sum scale

Advertising
background image

1-50

IM 04L51B01-01EN

Data That Can Be Used in Expressions
You can use the data shown below in expressions.

Data

Notation

Description

I/O channel data

0001, etc.

Specify channel numbers.

Math channel data

1

A001, etc.

Specify channel numbers.

Constant

K001 to K100

Values.

Communication channel data

2

GX20/GP20: C001 to C300

GX10/GP10: C001 to C050

Specify communication channel numbers.

Internal switch status

S001 to S100

1 or 0.

Flag

F01 to F20

1 or 0. Use the event action function to set

the flag (for details, see section 1.6).

1 /MT option

2 /MC option

Only the following types of data that are checked in the table below can be used in TLOG,

CLOG, and PRE.

Data

Comp. Type

I/O

channel

Math

channel

Communication

channel

Constant

Internal

switch

Flag

TLOG

CLOG

PRE

Other computations

Bad examples: TLOG.SUM(S01), CLOG.AVE(0001.0002.K01), PRE(S01)

Decimal Place

Set the decimal place for span lower and span upper.

Span Lower, Span Upper

Set the measurement range.

The decimal place is determined by the

Decimal place setting.

Unit

Set the unit of computed values.

TLOG

Setup Item

Selectable Range or Options

Default Value

Timer type

Timer, Match Time Timer

Timer

Timer No.

1, 2, 3, 4

1

Sum scale

Off, sec, min, hour

Off

Reset

Off, On

Off

Timer type

Set the timer type.

Timer No.

Set the number of the timer that you want to use.

Sum scale

Set the sum scale depending on the unit of measured values.

Set the sum scale when using sum computation (TLOG.SUM).

Example: If the unit of the measured value is “m

3

/min,” select

/min.

If you select Off, the measured data is summed as-is once per scan interval.

1.5 Configuring Math Channels