152
Fabric OS Message Reference
53-1003140-01
ANV-1004
5
ANV-1004
Message
S<slot number>,C<chip index>: Invalid DMA ch pointer, chan:<Channel number>,
good_addr:0x<Good address> bad_addr:0x<Bad address>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade
the data traffic.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.
ANV-1005
Message
S<slot number>,C<chip index>,A<anvil id>: Memory allocation failed.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates memory allocation failure in the software.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the switch or contact
your switch service provider.
ANV-1006
Message
S<slot number>,C<chip index>: HW ASIC Chip fault. Type = 0x<chip error type>,
Error = <chip error string>.
Message Type
LOG
Severity
CRITICAL
Probable Cause
Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders the
chip as not operational.
Recommended
Action
Restart the system at the next maintenance window. If the problem persists, replace the blade.