EM-1050
5
Recommended
Action
No action is required.
EM-1050
Message
FRU <FRU Id> removal detected.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that a field-replaceable unit (FRU) of the type and location specified by the FRU ID value was
removed from the chassis.
Recommended
Action
Verify that the FRU was intended to be removed. If not, replace the FRU as soon as possible.
EM-1051
Message
<FRU Id>: Inconsistency detected, FRU reinitialized.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that an inconsistent state was found in the field-replaceable unit (FRU). This occurs if the state
of the FRU was changing during a failover. The FRU is reinitialized and the traffic may have been
disrupted.
Recommended
Action
No action is required.
EM-1057
Message
Blade:<Slot Id> is getting reset:<Fault reason>.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the blade is being automatically reset because of known resetable transient errors such as
an application-specific integrated circuit (ASIC) parity error.
Recommended
Action
No action is required if the switch does not reach the reset threshold for the switch or blade. If the reset
threshold is reached on the switch or blade, the switch or blade will be faulted and should be replaced.