Swch-1010, Swch-1011, Swch-1012 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 933

Fabric OS Message Reference
911
53-1003140-01
SWCH-1010
5
SWCH-1010
Message
Trunk Area (TA) enabled on slot <slot number> with switch not in PID format 1. TA
enabled ports will be persistently disabled.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the blade is enabled with the port configuration that had Trunk Area enabled previously.
Recommended
Action
Disable Trunk Area on ports that had Trunk Area enabled previously. Refer to the Fabric OS
Administrator's Guide for more information.
SWCH-1011
Message
HA out of sync: Stby CP (ver=<standby SWC version>) doesn't support Trunk Area
functionality. (active ver=<active SWC version>, TA enabled on sw=<'1' if Trunk
Area ports exist; Otherwise '0'>).
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.
Recommended
Action
Load a firmware version on standby CP that supports Trunk Area functionality by using the
firmwareDownload command.
SWCH-1012
Message
Trunk Area (<trunk area>) has been enabled for one or more ports.
Message Type
AUDIT | LOG
Class
CFG
Severity
INFO
Probable Cause
Indicates that a Trunk Area has been enabled for one or more ports and the configuration file has been
updated.
Recommended
Action
No action is required.