Fcr-1100, Fcr-1101, Fcr-1102 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 431

Fabric OS Message Reference
409
53-1003140-01
FCR-1100
5
FCR-1100
Message
16G EX_Port ICL topology for fabric <Fabric ID> is unbalanced.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the current configuration of the EX_Port inter-chassis link (ICL) paths are unbalanced.
Recommended
Action
Investigate the current EX_Port ICL configuration to ensure that all recommendations for cabling are
satisfied. Once cabling recommendations are satisfied, FCR-1101 message will be generated confirming
ICL paths are balanced.
FCR-1101
Message
16G EX_Port ICL topology for fabric <Fabric ID> is balanced.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the existing EX_Port inter-chassis link (ICL) configuration that was resulting in an
unbalanced topology for the corresponding fabric has been corrected.
Recommended
Action
No action is required.
FCR-1102
Message
ICL EX_Port <Port Numbers> need to be present in base switch to make a recommended
topology.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that some of the ICL ports in a quad small form-factor pluggable (QSFP) are not present in the
base switch. Ideally, all ports in the QSFP group should be present in the base switch.
Recommended
Action
Move the specified ICL EX_Ports of the QSFP group into the base switch using the lscfg --config
command.