Cdr-1010, Cdr-1011, Cdr-1012 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual

Page 253

Advertising
background image

Fabric OS Message Reference

231

53-1003140-01

CDR-1010

5

CDR-1010

Message

S<slot number>,C<chip index>: Internal monitoring of faults has identified suspect

hardware, blade may need to be reset or replaced: fault1:0x<fault1_cnt>,

fault2:0x<fault2_cnt> thresh2:0x<threshold_used>.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that above-normal errors observed in hardware that may or may not impact the data traffic.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

CDR-1011

Message

S<slot number>,P<port number>(<blade port number>): Link Timeout on internal port

ftx=<frame transmitted> tov=<real timeout value> (><expected timeout value>)

vc_no=<vc number> crd(s)lost=<Credit(s) lost> complete_loss:<complete credit

loss>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or more credits have been lost on a back-end port, and there is no traffic on that port
for two seconds.

Recommended

Action

Turn on the back-end credit recovery to reset the link and recover the lost credits. If credit recovery has
already been turned on, the link will be reset to recover the credits and no action is required.

CDR-1012

Message

S<slot number>,P<port number>(<blade port number>): Port Fault: Hard <Hard

fault>(<Fault reason>) fault1=<Fault1 count> fault2=<Fault2 count> (0x<LIP and

LLI fault count> 0x<RX_FIFO and HSS fault count> 0x<BWAIT fault count>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified port has failed. Port initialization will be retried.

Recommended

Action

Replace the SFP transceiver and the cable and then re-enable the port.

Advertising