Fw-1426, Fw-1427, Fw-1428 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 583

Fabric OS Message Reference
561
53-1003140-01
FW-1426
5
FW-1426
Message
Switch status change contributing factor Power supply: <Number Bad> bad, <Number
Missing> absent.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of faulty or missing
power supplies is greater than or equal to the policy set by the switchStatusPolicySet command.
Recommended
Action
Replace the faulty or missing power supply.
FW-1427
Message
Switch status change contributing factor Power supply: <Number Bad> bad.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of faulty power
supplies is greater than or equal to the policy set by the switchStatusPolicySet command.
Recommended
Action
Replace the faulty power supply.
FW-1428
Message
Switch status change contributing factor Power supply: <Number Missing> absent.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the switch is not in a healthy state. This occurred because the number of missing power
supplies is greater than or equal to the policy set by the switchStatusPolicySet command.
Recommended
Action
Replace the missing power supply.