Spc-3008, Spc-3009, Spc-3010 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 873

Fabric OS Message Reference
851
53-1003140-01
SPC-3008
5
SPC-3008
Message
S<slot number containing Encryption Engine>, <module name>: SP crypto got READY
notification.
Message Type
LOG
Severity
INFO
Probable Cause
Indicates that the key application (KPD) within the CryptoModule of the encryption engine has been
started.
Recommended
Action
No action is required.
SPC-3009
Message
S<slot number containing Encryption Engine>, <module name>: FIPS certificate
mismatch, certificate: <FIPS certificate is CO-0 or User-1>.
Message Type
LOG
Severity
ERROR
Probable Cause
Indicates that the Federal Information Protection Standard (FIPS) certificate within the CryptoModule
does not match that of the node.
Recommended
Action
Zeroize the encryption engine (after backing up any needed primary or secondary KEK), then execute
the cryptocfg --initEE and cryptocfg --regEE commands.
SPC-3010
Message
S<slot number containing Encryption Engine>, <module name>: SEK integrity failure
during initialization.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates the CryptoModule internal Secret Encryption Key has been corrupted or has not been
initialized.
Recommended
Action
Execute the cryptocfg --initEE and cryptocfg --regEE commands.